Rated supply voltage | ۲۴ to 240 VAC (50/60 Hz) ۱۲ to 240 VDC (Ripple 20% max. (Single-phase full-wave rectified power sources may be used for 24 to 240 VDC.)) |
---|---|
Operating voltage range | ۹۰ to 110% of rated supply voltage (21.6 to 264 VAC/10.8 to 264 VDC) |
Power consumption | Approx. 0.2 to 4 VA/Approx. 0.2 to 2 W |
Time ranges(Number of ranges) | ۷ |
Time ranges | ۰.۱ to 99.9 s ۱ to 999 s ۰.۱ to 99.9 min ۱ to 999 min ۰.۱ to 99.9 h ۱ to 999 h ۱۰ to 9990 h |
Input method | No-voltage input (open and short-circuit) |
Output modes | A: ON delay B: Repeat cycle C: Signal ON/OFF delay D: Signal OFF delay E: Interval F: One shot and flicker G: Signal ON/OFF delay H: Signal OFF delay |
Control output (Contact output) | Time-limit contact: SPDT Resistive load: 3 A at 250 VAC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
Reset system | Self-reset/External reset |
Power reset | Reset time: 0.5 s max. |
Display method | LCD 3 digit |
Ambient temperature (Operating) | -۱۰ to 55 ℃ (with no icing) |
Ambient humidity (Operating) | ۳۵ to 85% |
Accuracy of operating time | ±۰.۳% ±۰.۰۵ s (The values are based on the set value.) |
Setting error | ±۰.۵% ±۰.۰۵ s (The values are based on the set value.) |
Influence of voltage | ±۰.۳% ±۰.۰۵ s (The values are based on the set value.) |
Influence of temperature | ±۰.۳% ±۰.۰۵ s (The values are based on the set value.) |
Insulation resistance | ۱۰۰ MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between control output terminals and operating circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min |
Impulse withstand voltage | Between power terminals: 5 kV Between current carrying terminals and exposed non-current carrying metal parts: 5 kV |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s۲, ۳ times each in 6 directions Malfunction: 100 m/s۲, ۳ times each in 6 directions |
Life expectancy | Electrical: 100,000 operations min. (3 A at 250 VAC resistive load at 1800 operations/h) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
Degree of protection | IP40 |
Mounting method | Surface mounting |
External connection method | Front screw terminals |
Weight | Approx. 190 g |